NEWS:
We expect the access will be more restrictive starting on the Friday.
The first collision is scheduled on Feburary 11.
iFIX UPGRADE:
All the servers, S1 to S5, and SOL2 are now upgraded and running on the new
iFIX version 3.0. We are a couple of days behind in schedule. A few
the problems caused the delay. First, the Pentium II machines were very slow
with iFix 3.0. This caused a lot of confusion. However, in retrospect, this
problems turned out to be not so critical. The other problem was due to a
bad CD ROM driver.
So far the new version coexits with the old version without too much trouble.
MUON3:
Yeongdae tried to figure out the known problem, which causes trigger inhibit
right after HV was recovered after trip. According to his explanation
this was due to the fact that software trip signal occurs after hardware
trip was fully recovered. Please see more details in his transparancies.
TRIGGER INHIBIT:
Software trigger inhibits for the systems, PLUG and CLC need to be installed.
Luciana is working on PLUG. We do not have information on CLC.