CDF Crate (VIPA CDF Subrack)
CDF2388 document entitled "A Standard Front-End and Trigger VMEbus Based Readout Crate for the CDF Upgrade - The CDF Readout Crate"
CDF2388.htm in html format
CDF2388.ps in postscript format
CDF2388.doc
in Microsoft Word format
The Care & Feeding of VIPA64x Subracks at Fermilab
from Fermilab's PREP department
Board Design Guide for CDF VME64 Extensions Modules & VIPA Subracks
Design Guide in html format
Design Guide in postscript format
Design Guide in Microsoft Word format
VME Crate Power Spec Spreadsheet
6U-to-9U Adapter
Documentation on an adapter for using a 6U commercial Motorola MVME-162 VMEbus processor card in a 10U CDF Front End crate (9U for the cards plus 1U for electrical connections = 10U)
6U-to-9U Adapter.htm in html format
6U-to-9U Adapter.ps in postscript format
6U-to-9U Adapter.doc
in Microsoft Word format
Stiffeners for 9U printed circuit boards
There are two approaches that have been implemented. They are described below.
1) This design is suitable for both the main module (9Ux400mm) and transition card (9Ux120mm). It should be located close to the VMEbus connectors on the circuit board. This design is mechanically very strong. However, it takes up a significant amount of real estate on the component side of the board. For most board layouts this will not be a problem. In the case where a printed circuit board is very densely packed near the connectors or in the case where a layout has been implemented without reserving space for this style of stiffener, the altenatives described in the following section should be utilized.
Stiffener for both main and transition modules
in postscript format
2) This design was implemented with a goal of minimizing the amount of board real estate that is lost to the stiffener footprint. This is accomplished by locating the stiffener on top of the VMEbus connectors and sharing four of the required six mounting screws for the stiffener with the four screws used to mount the J1 and J2 connectors. Two additional dedicated screws are required to mount these stiffeners. For one of these two screws, the board designer can select between two holes in the stiffener located just above the J3/J5/J6 location. There is one model for the 9Ux400mm main module and another model for the 9Ux120mm transition card. The two models are not interchangable. Both of these models require two metal standoffs to be positioned over the stiffener mounting screws that are located on either side of the J3/J5/J6 connector location.
Stiffener for 9Ux400mm main module in postscript format
Stiffener for 9Ux400mm main module
in pdf format
Stiffener for 9Ux120mm transition card in postscript format
Stiffener for 9Ux120mm transition card
in pdf format
Crate Load Card
used for providing an electrical load and a thermal load in order
to conduct tests of the power supplies and the cooling system
Connectors, front panel and J3 backplane
Options for crate power distribution
VME64-9U Extensions document
VME International Physics Association (VIPA)
VME International Trade Association (VITA)