From: FNALD::KPITTS "Kevin Pitts" 14-NOV-1998 13:44:37.22 Subj: calibration pulse delays Here are my estimates for the variations in the arrival time of the calibration strobe at the various ASDQ daughterboards. SL E/W ucoax TDC slots min delay max delay -- --- ----- --------- --------- --------- 1 E 14' 4-5 0.0 by def 0.4ns 2 W 14' 4-5 0.0ns 0.4 3 W 13'6" 6-8 -0.8 0.0 4 E 13'6" 5-8 -1.1 0.0 5 E 13' 8-12 0.0 1.5 6 W 13' 8-12 0.0 1.5 7 W 12'6" 12-17 0.7 2.6 8 E 12' 12-17 0.0 1.8 The "TDC slots" column lists the lowest and highest slots that any TDC from a given SL resides in. The minimum and maximum delay are calculated relative to a SL1 board in slot 4. The delay is calculated as: delay = (slot - 4)*0.37ns/slot - (1.5ns/foot)*(length-14') ^slot-to-slot ^cable length I have assumed that the delay across the backplane is 7ns from end to end (slots 2->21), which translates to 0.37ns/slot, assuming it's linear across the backplane. I have assumed 1.5ns/foot for the ucoax. So the range of delays is -1.1ns to +2.6ns. Given that the delay through the ASDQ is about 12ns, it looks like it is fine to keep all of the flat cable lengths the same. This calculation assumes the TRACER to be in slot 2. If we put it in the middle, the range gets worse, because as it is now, the backplane delay is somewhat compensated by the shorter ucoax lengths for the outer SLs. Unless anybody has a problem with this, I will update the baseline calibration plan to include all flat cables the same length. Also, I will update our readout mapping to have the TRACER in slot 2.