CDF SVXII Pigtail Low Voltage Power Cable Specification ======================================================= a) Number and gauge of conductors 24 Conductors 2 20 AWG 8 22 AWG 2 24 AWG 12 26 AWG b) Type/grade of wire commercial stranded c) Coding of conductors. Color coding or numbering: depending on price. d) Tape barrier used as protective layer. None. If a protective layer is necessary use lowest mass option. Paper? e,f) Electrical shielding None g)Jacket TPE or polyethylene. h)Color of outer jacket, sheath markings. Not important. i) Wall thickness of outer jacket. As thin as possible while still meeting VW1 fire safety standard. j) Physical or environmental requirements. Physical: Length tolerance: 1/2 inch Diameter tolerance: None Overall tensile strength: Not applicable Weight limitations: ask Minimum bending radius: 3 inches Environmental Requirements: Minimum and maximum operating temperatures: 0 to 100/120 degrees C Physical abuse: Not applicable Surrounding Medium: Air, Nitrogen Electrical Requirements: Voltage Rating of insulation: 20V Maximum current per conductor: 20 AWG 1.3 Amp 22 AWG 0.8 Amp 24 AWG 0.48 Amp 26 AWG 0.27 Amp Amount of Electrical or Magnetic Shielding: None Capacitance requirements: none k) Minimum and maximum overall diameter: As small as above allows. Note: if possible we would prefer not to use any filler material.