| Subject |
Status |
Conclusions |
Comments |
|---|---|---|---|
| Review of Error Rates |
Done |
Total error rate ~10E-6 |
|
| Trigmon Monitoring Status |
Ongoing |
Running in control room |
Still has a rare &
unreproducable crash to debug |
| Modification to HRR |
Done |
Reduced to 0 number of HRRs
between 240e30 and 200e30 [still 21 event corruptions]. Previously one
HRR ~ every two minutes. |
|
| Spares |
|||
| Stereo finders |
Done |
2 good stares that have been
tested in beam, 2 more still to test |
|
| XTCs |
Done |
Nils says there are enough till
the end of Run II |
|
| Pulsars |
Done |
1 hot spare with correct
firmware + 1 board used for testing |
|
| XFT Mez |
Done |
2 on hot pulsar spare + 4 on
test pulsar + 2-3? in test stand room |
|
| Masking of Fibers |
Ongoing |
Run control gets info about
masked on fibers from the database, then sends to the control node. The
control node sends to L2 PC. At the L2 PC the info is passed ot the
trigger alrogirtihim, which auto-accepts if any region of track window
overlaps with a masked on XTC |
By whole UC Davis L2 XFT Upgrade
Group |
| New TL2D Format |
Ongoing |
New format agreed on & new
accessors written. Implemented online. Still needs to be checked, still need to update CDF Note 4152 |
By whole UC Davis L2 XFT Upgrade Group, with special emphasis on Alison |