Trigger / Algorithm Performance - L2 Stereo Upgrade

Muon Test Triggers

Subject
Status
Conclusions
Comments
Study of valid tracks with large Delta(3-5-7) (using CMX)
Done


Addition of CMP information to CMUP test trigger
Ongoing

Aron
Re-optimization of pointing cuts
Ongoing

Aron

Delta(3-5-7) Changes

Subject
Status
Conclusions
Comments
Optimization of efficiency vs d357
Done
-Delta(3-5-7) < 25 is in the plateau, efficiency (full luminosity range) drops by about 0.5% when going to SL3 mask only, efficiency vs Delta(3-5-7) shape stays the same for high luminosity


Measures of performance
Subject
Status
Conclusions
Comments
Efficiencies



       versus luminosity (offline)
Ongoing
Going to the valid track approach reduced luminosity dependence.

       as a function of L3 bits
Done
CMX ~95% sloped, CMUP ~98% flat, CEM ~99% flat wrt L3

Trigger Rates



       projections (HTTF) Done
Matches data rates

       online (XMon-Pre-Shutdown) Done
Rates as predicted by offline studies

       online (XMon-Post-Shutdown)
Done
Show good agreement with pre-shutdown results

Timing



       versus luminosity Done


       versus # of tracks Done


Number of Attempted Tracks



       for different triggers Done
Behavoir seems reasonable.

       versus instanteous luminosity Done
CMX ~1.1, CMUP ~1.1, CEM ~1.3

Stereo Reconstruction Efficiency & Rate Reduction



       efficiency (L3 Bits) versus luminosity (online)
Done
CMX ~96% some slope, CMUP ~97% flat, CEM ~99% flat wrt L3

       efficiency (L3 Bits) versus # of tracks Done


       Find and solve source of reconstruction inefficiency
Done
99.8% Efficiency versus offline

Using Recent Data to Compare Online and Offline



       ROL0 pixels from data to check Z0/cotan
Done
Agreement between online and offline

       ROL0 pixels to check decision
Ongoing

Rob
       ROL0 pixels to study difference between axial and offline or L3 tracks
Ongoing

Charles

XTCs Masked on, SL3, SL5, SL7
Subject
Status
Conclusions
Comments
Change Reconstruction code to auto accept based on   regions
Done

Offline

pT Dependence
Subject
Status
Conclusions
Comments
of Efficiency
Done
Stable, both in magnitude and slope for a set of matching requirements similar to the default one. We should continue to use the default.
This is what we want.
of Resolution
Ongoing

Rob

Simultaneous Operation of 2 Algorithims
Subject
Status
Conclusions
Comments
Making both triggers available to the trigger table
Done



Digitization for Z5 and Cotan
Subject
Status
Conclusions
Comments

Done
Current digitization method is adequate