Plan for Online Luminosity measurements
during the CDF Commissioning Run
Baseline
-
Hit counting method to Tevatron
and CDF
-
Use sum(hits) for East and West as estimator
-
Hits are defined by Xilinx threshold and show directly
in DPM input
-
Use high threshold to pickup single "pp" (primary particle)
-
Start with 50% of expected peak
-
Use formula from GEANT simulation
Lum=f(N_hits)
-
Use CDFCLK to strobe the
Dual Port Memory
-
Need to find offset between B0 signal and its corresponding
data
-
Use LED to estimate, and real data for final offset
-
We will have data for abort gap also - for background
studies
-
Z centroid for
Tevatron "cogging" studies
-
Use East/West coincidence and asymmetry
rate algorithm from GEANT simulation
-
Implement an ACNET variable for
Z centroid
Additional
-
Empty crossing
method in parallel to "hit counting"
-
Calculate fraction of crossings
with no hits
-
has to be same "hit" definition
because of single Xilinx threshold
-
Calculate Luminosity based on formula
for empty crossings
-
Need acceptance from simulation
-
Output luminosity per bunch to ASCI
file, together with "hit method" luminosity